K200-150-400a
       Type K centrifugal cantilever single-staged pumps with horizontal axial intake of liquid to the impeller are designed for pumping, in stationary conditions, of pure water (except sea water) with pH=6-9 and temperatures from 0° C to 85° C (up to 105° C if double gland seal is used) as well as of other liquids similar to water in density, viscosity and chemical activity and containing solid impurities of not more than 0,1% in volume and less than 0,2 mm in size.
       In the type K pumps the motor shaft torque is lead on the pump shaft by the means of the flexible coupling.
TECHNICAL CHARACTERISTICS
Flow rate, m3/h | 400 |
Head, m | 40 |
Power, kW | 75 |
Height of self-suction, m | 5 |
Frequency, rpm | 1450 |
OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNITThe mark of el. motor | Power, kW | L | l | l1 | l2 | l3 | l4 | l5 | H | H1 | h | h1 | B | d2 | C | Pump mass, kg | Unit mass, kg | 5AM250 S4 | 75 | 1750 | 830 | 160 | 12 | 150 | 600 | 1550 | 885 | 825 | 435 | 70 | 795 | 33 | 700 | 250 | 960 |
Dy | D | D1 | D2 | d | n | Dy1 | D3 | D4 | D5 | n1 | d1 | 200 | 335 | 295 | 268 | M20 | 8 | 150 | 280 | 240 | 212 | 8 | 22 |
|