K 150-125-250
       Type K centrifugal cantilever single-staged pumps with horizontal axial intake of liquid to the impeller are designed for pumping, in stationary conditions, of pure water (except sea water) with pH=6-9 and temperatures from 0° C to 85° C (up to 105° C if double gland seal is used) as well as of other liquids similar to water in density, viscosity and chemical activity and containing solid impurities of not more than 0,1% in volume and less than 0,2 mm in size.
       In the type K pumps the motor shaft torque is lead on the pump shaft by the means of the flexible coupling.
TECHNICAL CHARACTERISTICS
Flow rate, m3/h | 200 |
Head, m | 20 |
Power, kW | 18,5 |
Height of self-suction, m | 4,2 |
Frequency, rpm | 1450 |
OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNITThe mark of el. motor | Power, kW | L | l | l1 | l2 | l3 | l4 | l5 | H | H1 | h | h1 | B | d2 | C | Pump mass, kg | Unit mass, kg | AIR160M4 | 18,5 | 1335 | 670 | 140 | 145 | 237 | 700 | 1102 | 675 | 455 | 320 | 40 | 475 | 24 | 395 | 140 | 370 |
Dy | D | D1 | D2 | d | n | Dy1 | D3 | D4 | D5 | n1 | d1 | 150 | 280 | 240 | 212 | M20 | 8 | 125 | 245 | 210 | 184 | 8 | 18 |
|