K 100-65-250
       Type K centrifugal cantilever single-staged pumps with horizontal axial intake of liquid to the impeller are designed for pumping, in stationary conditions, of pure water (except sea water) with pH=6-9 and temperatures from 0° C to 85° C (up to 105° C if double gland seal is used) as well as of other liquids similar to water in density, viscosity and chemical activity and containing solid impurities of not more than 0,1% in volume and less than 0,2 mm in size.
       In the type K pumps the motor shaft torque is lead on the pump shaft by the means of the flexible coupling.
TECHNICAL CHARACTERISTICS
Flow rate, m3/h | 100 |
Head, m | 80 |
Power, kW | 55 |
Height of self-suction, m | 4,5 |
Frequency, rpm | 2900 |
OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNITThe mark of el. motor | Power, kW | L | l | l1 | l2 | l3 | l4 | l5 | H | H1 | h | h1 | B | d2 | C | Pump mass, kg | Unit mass, kg | 4AM200 L2 | 45 | 1390 | 625 | 125 | 145 | 237 | 700 | 1194 | 520 | 605 | 270 | 40 | 568 | 24 | 490 | 95 | 460 |
Dy | D | D1 | D2 | d | n | Dy1 | D3 | D4 | D5 | n1 | d1 | 100 | 210 | 180 | 158 | M16 | 8 | 65 | 180 | 145 | 122 | 4 | 18 |
|