14 NDS-N (510)

the version for printing

model

       The ND-type horizontal single-stage double-entry pumps are designed for pumping petroleum products: crude oil, automobile and aircraft petrol and diesel fuel at temperatures from 278° K to 318° K (from 5° C to 45° C).

TECHNICAL CHARACTERISTICS

Flow rate, m3/h1000
Head, m36
Power, kW129
Height of self-suction, m5,2
Frequency, rpm960


OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNIT

The mark of el. motorPower, kWVoltage, VLL1ll1AA1BB1HhWeight, kG

VAO2-280L6

160

380/660

2800

2185

425

1235

615

710

1645

790

1345

915

-


overall and mounted dimension the pump units

MOUNTING DIMENSIONS OF THE PUMP


LL1ll1l2l3l4l5BB1HH1H2H3hA1A2

1470

805

900

500

820

480

820

480

1647

900

1100

670

482

372

85

700

700

A3DD1D2D3D4D5D6D7dd1d2d3nn1bWeight, kG

700

580

525

490

400

520

470

438

350

30

27

34

80

16

16

22

1684


mounted dimensions of pump