CN 160/112
       The CN-type horizontal single-stage double-entry pumps are designed for pumping water as well as jet engine fuel, automobile and aircraft petrol and diesel fuel at temperatures from 258° K to 323° K (from -15° C to 50° C).
TECHNICAL CHARACTERISTICS
Flow rate, m3/h | 160 |
Head, m | 112 |
Power, kW | 77 |
Height of self-suction, m | 4,8 |
Frequency, rpm | 2900 |
OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNITThe mark of el. motor | Power, kW | Voltage, V | L | L1 | l | l1 | A | A1 | B | B1 | H | h | Weight, kG | 2V250M2 | 90 | 220/380/660 | 1850 | 1330 | 175 | 625 | 450 | 510 | 820 | 604 | 885 | 300 | 920 |
MOUNTING DIMENSIONS OF THE PUMPL | L1 | l | l1 | l2 | l3 | l4 | l5 | B | B1 | H | H1 | H2 | H3 | h | A1 | A2 | 755 | 430 | 450 | 210 | 340 | 160 | 340 | 160 | 640 | 300 | 570 | 300 | 181 | 146 | 39 | 330 | 260 | A3 | D | D1 | D2 | D3 | D4 | D5 | D6 | D7 | d | d1 | d2 | d3 | n | n1 | b | Weight, kG
| 260 | 280 | 240 | 212 | 150 | 215 | 180 | 150 | 100 | 22 | 18 | 23 | 36 | 8 | 8 | 10 | 185
|
|