CNSk 60-99

       The pump is designed to transfer neutral and acid waters with pH=6,5, the contents of the mechanical impurities not more than 0,2%, and the size of solid particles not more than 0,2mm.
TECHNICAL CHARACTERISTICS
| Flow rate, m3/h | 60 |
| Head, m | 99 |
| Power, kW | 24,6 |
| Height of self-suction, m | 5 |
| Frequency, rpm | 2950 |
OVERALL AND MOUNTING DIMENSIONS OF THE PUMP UNIT| The mark of el. motor | Power, kW | Voltage, V | L, mm | B, mm | H, mm | Weight, kG | 4AM180M2 | 30 | 220/380 | 1665 | 255 | 676 | 490 | VRP180M2 | 30 | 380/660 | 1768 | 255 | 775 | 505 |
 MOUNTING DIMENSIONS OF THE PUMP | L1, mm | L2, mm | L3, mm | L4, mm | Weight, kG | 300 | 190 | 300 | 950 | 250 |
|